CJRGP - 655135-003 LITHIUM THIONYL CHLORIDE CELL

  • MSDS: CJRGP
  • Manufacturer: BATTERY ENGINEERING INC
  • Product Name: 655135-003 LITHIUM THIONYL CHLORIDE CELL
  • National Stock Number: 6135-01-327-0279
Product Identification

Product ID:655135-003 LITHIUM THIONYL CHLORIDE CELL
MSDS Date:07/09/1999
FSC:6135
NIIN:01-327-0279
Status Code:A
MSDS Number: CJRGP

Responsible Party
BATTERY ENGINEERING INC
100 ENERGY DRIVE
CANTON, MA 02021
US

Emergency Phone: 800-255-1545(CHEMTEL)

Info Phone: 781-575-0800

Cage: 60289

Contractor
BATTERY ENGINEERING INC
CANTON, MA 02021 US

Telephone: 781-575-0800

Cage: 60289

Ingredients

LITHIUM

CAS: 7439-93-2

RTECS: OJ5540000


THIONYL CHLORIDE

CAS: 7719-09-7

RTECS: XM5150000


ALUMINUM CHLORIDE

CAS: 7446-70-0

RTECS: BD0525000


LITHIUM CHLORIDE

CAS: 7447-41-8

RTECS: OJ5950000

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: VAPOR VERY IRRITATING TO SKIN,
EYES, AND MUCOUS MEMBRANES. CHRONIC: OVEREXPOSURE CAN CAUSE
SYMPTOMS OF NON-FIBROTIC LUNG INJURY.
Explanation of Carcinogenicity:NONE LISTED.
Effects of Overexposure:EYE AND MUCOUS MEMBRANE IRRITATION.
Medical Cond Aggravated by Exposure:ASTHMA, OTHER RESPIRATORY
DISORDERS, SKIN ALLERGIES, AND ECZEMA.

First Aid

First Aid:EYE: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. HOLD EYELIDS
APART. SEEK IMMEDIATE MEDICAL TREATMENT. SKIN: RINSE WIT LARGE
AMOUNTS OF RUNNING WATER. IF BURNS DEVELOPS, SEEK MEDICAL
TREATMENT. INHALE: REMOVE TO FRESH AIR. IF BREATHING IS DIFFICULT,
ADMINISTER OXYGEN AND SEEK MEDICAL TREATMENT. INGEST: SEEK MEDICAL
TREATMENT.

Fire Fighting

Extinguishing Media:DRY LITHIUM CHLORIDE,GRAPHITE POWDER,PYRENE
G-1,LITH-X,CLASS D
Fire Fighting Procedures:COVER WITH DRY LITHIUM CHLORIDE,GRAPHITE
POWDER,LITH-X POWDER OR CLASS D FIRE EXTINGUISHER. DO NOT USE
WATER,MOIST SAND,CARBON DIOXIDE OR SODA ASH EXTINGUISHER.WEAR
PROTECTIVE BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:DO NOT SHORT CIRCUIT,RECHARGE,OVER
DISCHARGE,PUNCTURE,CRUSH OR EXPOSE TO TEMPERATURES ABOVE 100C.

Accidental Release

Spill Release Procedures:DO NOT BREATHE VAPORS OR TOUCH LIQUID WITH
BARE HANDS.
Neutralizing Agent:SODA LIME.

Handling

Handling and Storage Precautions:DO NOT SHORT CIRCUIT OR EXPOSE TO
TEMPERATURE ABOVE 100C. DO NOT RECHARGE, OVERDISCHARGE, PUNCTURE,
OR CRUSH.
Other Precautions:DO NOT STORE BATTERIES IN HIGH HUMIDITY ENVIRONMENTS
FOR LONG PERIODS.

Exposure Controls

Respiratory Protection:ACID GAS FILTER MASK
Ventilation:LOCAL EXHAUST
Protective Gloves:BUTYL RUBBER
Eye Protection:CHEMICAL WORKER SAFETY GLASSES
Other Protective Equipment:XHEMICAL LABORATORY SAFETY GLASSES AND
CHEMICAL APRON
Supplemental Safety and Health

Chemical Properties

HCC:Z6
Boiling Pt:=77.C, 170.6F
Melt/Freeze Pt:=-105.C, -157.F
Vapor Pres:92MM@20C
Vapor Density:4.1
Spec Gravity:1.63
Solubility in Water:DECOMPOSES
Appearance and Odor:THIONYL CHLORIDE-COLORLESS TO PALE
YELLOW,SHARP,PUNGENT ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:TEMPERATURES IN EXCESS OF 100C.HIGH
HUMIDITY FOR EXTENDED PERIODS.
Hazardous Decomposition Products:SULFUR DIOXIDE,HYDROGEN CHLORIDE

Disposal

Waste Disposal Methods:NEUTRALIZE SPILL WITH SODA LIME, SEAL LEAKING
BATTERIES AND SODA LIME IN PLASTIC BAG AND DISPOSE OF AS HAZARDOUS
WASTE.

Transport

Transport Information:DOT, IATA/ICAO: PROPER SHIPPING NAME: LITHIUM
BATTERIES. UN3090. HAZARD CLASS: 9. PACKING GROUP II.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.